Redundancy mode

The AoIP module is redundancy compatible. Redundancy allows the configuration of two connections for the AoIP system. This provides a more stable AoIP environment but requires equipements for 2 AoIP connections and only works with compatible elements. Redundancy allows connection between the two Ethernet ports of each device to the same or two distinct networks:

This makes the ISP work with a compatible ST2022-7 network device (Ravenna or AES67).

Notes :

Double configuration

To use the two available ports, please tick the “ST2022-7 mode” checkbox in the advanced WebUI of the AoIP option.

It is possible to use the two AoIP module ports in order to set up a command network and an AoIP network.

Note that some devices use a command Ethernet port and an in/out AoIP port. In that case, we recommend connecting two networks:

Be aware that the AoIP option does not have separated networks ports. The two ethernet connectors are acting like a switch of two ports with different IP addresses but on the same network.

Some incorrect configurations could bridge the command network and the AoIP network of some devices. Disconnect the second port of the AoIP option from the network to resolve such related issues.