The AoIP module is redundancy compatible. Redundancy allows the configuration of two connections for the AoIP system. This provides a more stable AoIP environment but needs the materials for both AoIP ports requires equipements for 2 AoIP connections and only works with compatible elements. Redundancy allows to connect connection between the two Ethernet ports of each device to the same or two distinct networks:

...

  • IP addresses configuration on the ISP:
    Open ISP device advanced page, either using ANEMAN or clicking on the IP in the “settings” Tabtab.
    Browse to the General > Network section.
    Make sure the ST2022-7 mode option is active.
    Configure the IP addresses on both Interface 1 and 2.
    Note : The IP addresses range should be in different IP ranges to avoid IP conflicts. Please see this page if you need help and details on IP addresses conflicts.
    Once configuration is complete, press on Apply & Reboot.

  • Configure the IP addresses on the device:
    Connect the two networks to your compatible device and set an IP address for both networks.

  • Set the audio connections in the Advanced pages
    Open the Merging device advanced page, either use ANEMAN or click on the IP in the “settings” tab.
    In the General Settings page, Multi-InterfaceST2022-7 mode should be enabled, and both Interfaces Links should be Up.
    You can now create a source or sink with ST2022-7. The other settings are configurable as well at this point.